Xrf analysis providers in Chelmsford, MA right now? MicroVision Laboratories’ analytical experts were able to meet with the QC Engineers and develop an analytical plan as to which solder joints to cross section and inspect. The client not only wanted to determine if there were any significant issues with the solder joint but also determine that there was a good intermetallic bond between the tin/lead solder and the copper wires of the chip packages.
Conclusion: Based on the analytical report, the client was able to demonstrate that the particles were consistent with a common aspirin tablet. When the end customer was approached with this report, they remembered that their spouse had taken an aspirin earlier that morning, and had likely used the bottle of water in question to do so. Based on this, the customer was happy, the manufacturing client was satisfied, and the sample was maintained – undestroyed should someone need to examine the sample again or do any more esoteric testing. For an affordable price, the client was able to get piece of mind, and gather information from a very wide range of testing methods quickly and accurately.
The data indicated that a significant portion of the dust was from the insulation in the attic. The contractor had replaced a portion of duct work running to the master bedroom. During this replacement, fiberglass insulation was knocked into the ducting. The small glass insulation fibers were spread through the AC ducts and settling out of the air throughout the house. The client was relieved to know what was causing their skin irritation and the significant dust build up. Using the results garnered from the analysis from MicroVision Labs they were able to have the contractor clean out the duct work and act to prevent further spread of the insulation fibers and properly clean up the settled dust in the house that was the cause of the homeowner’s skin irritation.
We are proud to announce that MicroVision Labs is now accredited to the ISO/IEC 17025:2017 standard. This represents over a year of diligent effort from all of our staff to verify and validate our in house SOP’s and transform our quality management system to one that is compliant to this international standard. This certification requires that accredited labs demonstrate that they are competent and can produce technically valid data and results unlike other certifications such as ISO 9001:2015. This represents an obvious value to our clients. Explore even more details on Microvision labs edx analysis.
Have you always been located in Chelmsford, MA? No, for the first four years MicroVision Labs operated at 15 A Street, Burlington, MA. In 2007 we moved to our present location in Chelmsford, MA. What business designation does MicroVision Labs have? MicroVision Labs is designated as a veteran owned small business. How many staff members does MicroVision Labs have? MicroVision Labs is a small business employing 5-10 full-time, part-time, and contract employees.
Energy Dispersive X-Ray Spectroscopy (EDS): While in a Scanning Electron Microscope (SEM), samples are exposed to high energy electrons in a vacuum, which generates X-rays through secondary electron transitions. Variations in electron configuration specific to each element generate different energy electrons, and thus different signature energy peaks, indicating which elements are present in the sample. Analysis is performed only on areas which are exposed to the electron beam, facilitating precise control of the analyzed area. This means the composition of very small areas or particles in a sample can be taken. Since EDS is performed in the SEM chamber, a quick and easy interrogation of the surface materials as viewed on the SEM is possible. This can be expanded to include the entire sample, please see our Elemental Mapping page. Additionally, relative amount of the elements present can be calculated, generating composition percentages. See extra details on https://microvisionlabs.com/.