Coriolis meter manufacturer from China

Quality turbine mass flow meter factory: What is the difference between a mass flowmeter and a volumetric flowmeter? Differene between Mass flow vs volumetric flow.If high accuracy is not required when measuring volumetric flow, volumetric flow meters are recommended. However, to compare results, volume flow meters need to be compensated for temperature and pressure. A mass flow meter, on the other hand, measures flow rate regardless of gas pressure or temperature. Read extra information on turbine mass flow meter.

What media can gas turbine flow meters measure? Is it good to use? Many industries rely heavily on the use of measuring tools, because many media must be measured before the capacity can be known, which has a great impact on production. It is precisely because of this that the use of measuring tools cannot be ignored. Nowadays, the use of gas turbine flow meters can bring about stable effects and has attracted the attention of many industries. So which media can be measured? Will it work well? Measurement of non-conductive liquids, if the electromagnetic flowmeter is dominant in the flow measurement of conductive liquids, in the field of non-conductive liquid flow measurement, the electromagnetic flowmeter is powerless, and the vortex This is where flow meters come in handy. Small diameter pipes introduced in recent years.

Second, the gas turbine flow meter equipment has strong functions, low power consumption and superior performance. When it is sold in the industry, it is found that the functional advantages of this kind of flowmeter will be more perfect. In many gas distribution stations or gas When promoting in the station, I found that the advantages will be more diversified, and there are more and more advantages. Third, the configuration of the natural gas turbine flow meter instrument is more perfect, and it will be more and more widely used. As long as you take a fancy to the above clarity, it will be more convenient in the process of normal use. After this is used in many gas distribution stations, it is found that the measurement accuracy is higher.

Turbine Flow Meter has the characteristics of high accuracy, good repeatability, convenient installation and maintenance, and simple structure. Liquid flows through the turbine casing, causing the internal rotor to rotate. When the rotor rotates, an electrical signal is generated in the pickup coil. This signal is converted to engineering units (liters, cubic meters, gallons, etc.) on the applicable local display. Optional accessory modules can be used to export signals to other devices. Make sure the vortex flow meter model meets your specific needs. For your future reference, if this information becomes unreadable on the turbine, it may be useful to record it on the nameplate of the manual. See the nameplate for your custom product specifications. Read additional info on https://www.bjssae.com/.

Beijing Sincerity Automatic Equipment Co., Ltd was reformed from the Petrochemical Branch Automatic Equipment Co.,Ltd. Beijing Sincerity is the innovation developed enterprise invested by both the China Petroleum &Chemical Corporation’s Beijing Research Institute of Chemical Industries and the Capital Science and Technology Group. Please be noticed, that all the videos taken are approved by SGS, Switzerland, or TUV, Germany. All the videos are real and without shooting skills or beauty filters.

When the vortex gas flow meter is installed behind the pressure reducing valve, the saturated steam suddenly decompresses greatly, the fluid expands adiabatically, the water droplets partially evaporate, and at the same time absorbs the heat of vaporization from the liquid and vapor phases, reducing the temperature of the vapor and liquid phases. If the temperature is not lowered much or the humidity is higher before evaporation, the temperature will quickly drop to the saturation temperature corresponding to the new pressure, and a new equilibrium will be established. At this time, the steam is still saturated steam. If the pressure drops a lot or the humidity before evaporation If the temperature is lower, the temperature is still higher than the saturation temperature corresponding to the new pressure due to the evaporation of water droplets, and the steam becomes superheated steam.

China Capital technology group invested in the SINOPEC automation instrument department of Beijing institute of chemical industry. Beijing shouke shí huà automatic equipment Co., LTD (Beijing Sincerity’s predecessor) was officially established. “Shí huà” is the Chinese words from SINOPEC. Sincerity officially switched from a national company to joint-stock company. Beijing shouke shí Huá ( which is Beijing Sincerity Automatic Equipment Co., Ltd now ) was officially established. The Chinese pronunciation of “shí Huá “ and “ shí huà” are very close to each other. The 1st generation coriolis mass flow meters were officially launched. The coriolis mass flow meters are with all discrete components, little chips and LED digital display.